Document Library
The LECO Document Library is your primary source for instrument-based documentation, including brochures, application notes, webinars and presentations.
Brochures 95
Explore instrument capabilities, features, specifications, uses and benefits.
Reference Cards 23
Quickly access important product specifications, diagrams, spare or replacement part numbers and recommended consumables.
Consumable Catalogs
Request current consumables catalogsApplication Notes 410
Explore instrument capabilities across industries with technical insights and recommendations that optimize utility for your unique lab.
203-821-698 | Determination of Sulfur and Carbon in Lithium Iron Phosphate Battery Materials Carbon determination in Lithium Iron Phosphate is important as the Carbon content directly impacts the performance of this battery material. In addition, emerging battery technologies can take advantage of improved Sulfur utilization when LiFePO4 is used as an additive, making Sulfur determination in the base material an important quality control parameter. |
203-821-697 | Quantitation of Olefin Content in Plastic-Derived Pyrolysis Oils – QuadJet SD Comprehensive two-dimensional gas chromatography with flame ionization detection (GCxGC-FID) has proven to be one of the most effective analytical methods for analyzing complex mixtures, allowing for the detailed separation and identification of the hydrocarbons present while providing efficient, high-resolution chromatographic separations. |
203-821-669 | Determination of Nitrogen in Plastics The determination of Nitrogen is crucial in the material characterization and quality control procedures for the manufacturing and molding process of plastic materials. The LECO FP928 is a Nitrogen determinator that utilizes an automated Dumas combustion method and provides accurate and precise results in approximately five minutes. This eliminates involved sample preparation and the use of hazardous materials resulting in a cost-effective method for the quality control of plastic production. |
203-821-696 | Satisfying ASTM D8396 Requirements Paradigm GCxGC-FID This application note describes how to use a simple workflow with the LECO Paradigm system to fulfill the requirements of the ASTM D8396 test method to quantitatively determine mass % of total n-paraffins, iso-paraffins, naphthenes, 1-ring aromatics, and 2-ring aromatics using reverse-fill flush flow modulated comprehensive two-dimensional gas chromatography–flame ionization detection (GCxGC-FID). Understanding of bulk composition is crucial for fast-track certification of synthetic aviation fuels as outlined in ASTM D4054, and the more accurate group-type analysis results provided by GCxGC assist with streamlining the acceptance process. |
203-821-695 | CX300 Sectioning for Weld Evaluation For numerous applications, it is necessary to measure the quality of a weld, and there are several methods for doing so. Making a sacrificial test weld and using a microscope to measure the weld's critical areas is a popular technique. This procedure may require a lot of time and resources. However, by skipping the mounting and polishing stages, the work can be kept more efficient. Bypassing those phases in the metallographic sample preparation procedure, this "Cut and Etch" technique yields accurate readings. |
Videos and Webinars 104
- 1Non-Targeted Screening in Food: Boosting Food Analysis using GC×GC-ToF MS From 11 November 2024
- 2Moisture Determination in Milk and Milk Products From 17 October 2024
- 3Non-Targeted Screening in Sustainable Fuels: Exploring Method Development and Fuel Quality Assessment Using GCxGC-MS and Hyphenated Techniques From 27 September 2024
- 4Non-targeted screening in forensics, a discussion of method development and screening of forensic samples using GCXGC-TOFMS From 4 September 2024
- 5New Dimensions in Non-Targeted Screening of Complex Aroma Profiles From 1 August 2024
- 6Insights from Liege: Applying Non-Target GCxGC to Enhance Metabolomics Analyses From 27 June 2024
Posters and Presentations 220
- POPs Human Plasma BTX-GCxGC Comprehensive Non-Targeted Characterization of Persistent Organic Pollutants (POPs) in Human Plasma Using GCxGC with High-Performance TOFMS
- TOC Comparison Optimizing Performance Total Organic Carbon (TOC) Determination: Comparing Different Analytical Approaches and Optimizing Performance
- TOC Comparison Acid Treatment Total Organic Carbon (TOC) Determination: Comparing Two Different Approaches to Acid Treatment in Preparation for Combustion Analysis
- Cannabis Characterization BT-GCxGC Cannabis Characterization Using GC and GCxGC With Time-of-Flight Mass Spectrometry
- Essential Oil Fragrance Samples BT-GCxGC Paradigm Shift Non-Target Characterization of Complex Essential Oil and Fragrance Samples with GCxGC-MS-FID for Reliable Identification and Relative Quantitation in a Single Injection
- Synthetic Aviation Fuels RFF Splitter BT-GCxGC-Paradigm Shift Application of a Novel Reverse-Fill-Flush Modulator and Splitter for Simultaneous GCxGC-TOFMS/FID Analysis of Synthetic Aviation Fuels